International Journal of Pharmaceutical Investigation logo
Article

Evaluation of in vivo efficacy and toxicity of prednisolone- loaded hydrogel-based drug delivery device

1★, 1, 1, 1★ Corresponding author

  1. 1Department of Chemical Technology, Division of Pharmaceutical and Fine Chemical Technology, University College of Science and Technology, University of Calcutta, Kolkata, West Bengal, INDIA.

CORRESPONDENCE

Amit Kumar De

Department of Chemical Technology, Division of Pharmaceutical and Fine Chemical Technology, University College of Science and Technology, University of Calcutta, Kolkata, West Bengal, INDIA.

amitkumarde200401@gmail.com

Volume 3, Issue 4 · pp. 225-233 · 2013 · DOI: 10.4103/2230-973X.121308

ABSTRACT

Drugs prescribed for the treatment of moderate to severe inflammatory bowel disease (IBD) are associated with number of side effects. Targeted drug delivery is essential for the treatment of inflammatory bowel disease in order to increase efficacy and reduce toxicity. The established delivery system is designed on enzyme and time-based release of poorly soluble prednisolone, a drug of choice for the treatment of moderate to severe inflammatory bowel disease. Their pharmacological evaluation was done in 2,4,6-trinitrobenzene sulphonic acid (TNBS)-induced model of colitis in rat. The drug was administered once daily for 3 consecutive days. Visible severity of colitis, tissue to bodyweight ratio, tissue histology along with nitric oxide (NO), malondialdehyde (MDA) and myeloperoxidase (MPO) activity of colonic tissue were studied to estimate the efficacy of the drug-loaded delivery system. The highest efficacy was observed for formulation in which Eudragit RS100 (EU) was used along with guar gum (GG) in a ratio 2:5 for the preparation of delivery device. An effective recovery was observed from the study of tissue histology of animals treated with the drug-loaded optimized formulation and the biochemical parameters supported it. The toxicity of prednisolone (PD) was reduced significantly as predicted from thymus to body weight ratio of treated animals. GG and EU RS100 provided a newer bipolymer combination for the colon-targeted delivery of PD which increased its efficacy and reduced the toxic side effects. The in vivo experiments presented effective amelioration from colitis in TNBS-induced animal model of colitis.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    De, A. K., Bhattacharya, P., Datta, S., & Mukherjee, A. (2013). Evaluation of in vivo efficacy and toxicity of prednisolone- loaded hydrogel-based drug delivery device. International Journal of Pharmaceutical Investigation, 3(4), 225-233. https://doi.org/10.4103/2230-973X.121308

    Copyright and licence

    © 2013 Author(s)

    This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. CC BY-NC-SA 4.0